Data DOI: 10.15785/SBGRID/821 | ID: 821
7LVC Coordinates: Viewer, PDB (RCSB) (PDBe), MMDB
Hekstra Laboratory, Harvard University
Release Date: 16 Mar 2021
1. If this dataset is locally available, it should be accessable at /programs/datagrid/821
2. To download this dataset, please run the following command from your Terminal on a Linux or OS X workstation:
'rsync -av rsync://data.sbgrid.org/10.15785/SBGRID/821 .'
(Harvard Medical School, USA)
Depending on your location, faster access may be available from a Tier 1 site closer to your location
'rsync -av rsync://sbgrid.icm.uu.se/10.15785/SBGRID/821 .'
(Uppsala University, Sweden)
'rsync -av rsync://sbgrid.pasteur.edu.uy/10.15785/SBGRID/821 .'
(Institut Pasteur de Montevideo, Uruguay)
'rsync -av rsync://sbgrid.ncpss.org/10.15785/SBGRID/821 .'
(Shanghai Institutes for Biological Sciences, China)
3. After the transfer is completed, please issue the following command to verify data integrity:
'cd 821 ; shasum -c files.sha'
Storage requirements: 26G
Biological Sample:
Dihydrofolate reductase
Dataset Type:
X-Ray Diffraction
Subject Composition:
Protein
Collection Facility:
Beamline 24-ID-C, NE-CAT, APS, Argonne National Laboratory
Data Creation Date:
17 Jul 2019
Related Datasets:
None
Greisman, JB; Hekstra, D. 2021. "X-Ray Diffraction data for: Dihydrofolate reductase. PDB Code 7LVC", SBGrid Data Bank, V1, https://doi.org/10.15785/SBGRID/821.
E. coli DHFR by Native Mn,P,S-SAD at Room Temperature
Name | Additional Roles | Affiliation While Working on the Project |
---|---|---|
Jack B Greisman | Data Collector, Depositor | Harvard University |
Doeke Hekstra | PI | Harvard University |
This data was collected in three passes on a single crystal with the Pilatus detector raised by two panels for the second and third pass. This altered the beam center from that reported in the image headers and introduced a shadow on the detector. For data reduction, the beam center should be set to (290.5, 225.2), and the pixel mask provided in the "Processing Bundle" should be used. The experiment was conducted at 6.5 keV to improve the anomalous signal, but this introduced an additional harmonic in the incident X-ray beam. The resulting secondary diffraction pattern is only observed at low resolution, and was excluded from DIALS spot finding, indexing, and geometry refinement by setting d_max to 6 angstroms. All passes were processed separately in DIALS and merged together in AIMLESS to yield the final merged intensities.
Version:
version unreported
Reprocessing failed.
Version:
version unreported
Reprocessing failed.
Version:
version unreported
Reprocessing failed.
License: CC0
Terms: Our Community Norms as well as good scientific practices expect that proper credit is given via citation. Please use the data citation, as generated by the SBGrid Data Bank.